Failed run capacitors on systems under 10 years old
Why it happens here
The capacitors installed in many builder-grade units are not rated for the long cooling season in Lake Nona South. Running from April to October at full load wears them out faster than the label suggests. It is the single most common repair we do here.
Our approach
We test capacitance with a multimeter on every diagnostic and replace weak capacitors before they fail. We stock the common ratings on the truck so most repairs finish in one visit.